• VCT

    Volume Check Tester OBET2.3

    1. Ensure sample safety by using air.
    2. 17 "Touch Monitor Setting easily secured with respect to the visibility, and each set value is applied.
    3. Safety sensor is applied to the front for cylinder accident prevention worker accident.
    4. Self diagnosi

    Information

     

    Division Specifications Remarks
    Model Name Volume Check Tester OBET2.3 Tower Type
    Working Voltage 100-240VAC(85-264VAC), 50/60Hz  
    Standard(mm) 1,130(W) x 855(D) x 1,680(H) Excluding side shelves
    Weight 280kg  
    Main Supply pressure (external) More than 400kPa  
    Measuring pressure 50~200kPa Depends on product size.
    Operating Temperature range 15℃~28℃  
    Inspection time Select User Machine Time : 5sec
    Measurement Error L. Leak : ±1.0%, S. Leak : ±0.2% Temperature maintenance state
    Resolution L. Leak : 0.1%, S. Leak : 0.1%  
    Inspection items Finished product type  
    Option Specifications Additional contact options and Production inquiry